Using Automation to Manage the Retention, Detention and Drainage of Watersheds
Designing Detention Efficiently
The purpose of on-site detention is to store water for a period of time before it drains or overflows off-site to the stormwater conveyance system (e.g., storm drain pipe, ditch, channel, etc.). Above and below ground detention basins are typically designed to remain dry between storm events (Dry Detention) or maintain a permanent wet pool for aesthetics or recreation (Wet Detention).
Generally, post developed runoff is detained so that there will be no increase in peak discharge and no increase in erosive velocity downstream of the project site during 2, 10, 50 and 100-yr recurrence interval storm events.
With a real-time, dynamically adjustable slide gate valve, the smartPOND RTO system delivers maximum allowable outflow rates, thereby reducing detention volume requirements by up to 50%, depending on site-specific hydrologic characteristics and regulatory agency criteria.
WATCH SMARTPOND IN ACTION
How Does smartPOND RTO Work?
When programmed with hydrologic inputs, i.e., pre vs post peak discharge rates for selected design recurrence intervals and the stage versus storage relationship of the detention basin, the system measures water surface elevation (WSE) at given time increments and determines inflow rate. System logic then controls the slide gate valve opening ensuring outflow always matches allowable discharge, thus optimizing detention storage and eliminating unused space.
Stacking Up The Benefits
- Reduce Detention Volume by 25-50%
- Maximize Developable Space/Lot Yield
- Save Money by Reducing Infrastructure Costs
- O&M alerts
- Robust Components
- Self-Contained, Ready to Install System
How About Maintenance?
Owners/Operators have access to device health and monitoring data 24/7. Desired alerts can be sent via SMS text messages or email regarding battery or other information. An on-board camera is available allowing daily or on-demand photographs to be taken of the pond and surrounding area.